Confocal and Histological Features After Poly(Ethylene Glycol) Diacrylate Corneal Inlay Implantation

Aritz Bidaguren, Javier Mendicute, Iratxe Madarieta, Nerea Garagorri

Research output: Contribution to journalArticlepeer-review

8 Citations (Scopus)

Abstract

Purpose: To evaluate the in vivo biocompatibility of photopolymerized poly(ethylene glycol) diacrylate (PEGDA) intrastromal inlays in rabbit corneas. Methods: Sixty-three eyes of 42 New Zealand rabbits were included. Manual intrastromal pockets were dissected in 42 eyes. PEGDA inlays were obtained using a specifically designed photomask and were inserted in the intrastromal pocket of 21 eyes (inlay group); the remaining 21 right eyes did not receive any implant (pocket-only group). Twenty-one eyes with no intervention were used as controls. In vivo confocal microscopy (IVCM) was performed at every visit. After 2 months, rabbits were sacrificed and corneas removed for histological analysis. Results: Corneas remained clear in all but two animals, and five cases of corneal neovascularization were seen (P = 0.2). Inlays remained stable without evidence of lateral or anterior migration, and no other complications were observed. No changes in anterior and posterior keratocyte density (P = 0.3 and P = 0.1, respectively) or endothelial cell density (P = 0.23) were observed between groups during the study time by IVCM. On pathology samples, thinning of the epithelium over the inlay area and epithelial hyperplasia over the edges were observed. A polygonal empty space with no evidence of PEGDA hydrogel within the midstroma was seen in the inlay group. Keratocytes were normal in shape and number in the vicinity of the PEGDA implant area. Conclusions: Photopolymerized PEGDA intrastromal inlays have shown relatively good safety and stability in rabbit corneas. Inlays were biostable in the corneal environment and remained transparent during follow up. Translational Relevance: The investigated PEGDA is promising for the development of biocompatible intrastromal implants.
Original languageEnglish
Article number39
Pages (from-to)39
Number of pages1
JournalTranslational Vision Science & Technology
Volume8
Issue number6
DOIs
Publication statusPublished - Nov 2019

Keywords

  • Confocal microscopy
  • Poly(ethylene glycol) diacrylate
  • Hydrogel
  • Intracorneal inlay
  • Corneal stroma

Project and Funding Information

  • Funding Info
  • Supported in part by the Spanish Ministry of_x000D_ Science and Education through Apply Research, grant_x000D_ MAT2006-13708-CO2-01. The authors alone are_x000D_ responsible for the content and writing of the paper._x000D_ Disclosure: A. Bidaguren, None; J. Mendicute,_x000D_ None; I. Madarieta, Tecnalia (E); N. Garagorri,_x000D_ Tecnalia (E)