TY - JOUR
T1 - Multi-pad electrode for effective grasping
T2 - Design
AU - Popović-Maneski, Lana Popovica
AU - Kostić, Milos
AU - Bijelić, Goran
AU - Keller, Thierry
AU - Mitrović, Sindi
AU - Konstantinović, Ljubica
AU - Popović, Dejan B.
PY - 2013
Y1 - 2013
N2 - We designed a new surface multi-pad electrode for the electrical stimulation of the forearm that is effective in controlling functional grasp in hemiplegic patients. The electrode shape and size were designed on the basis of the surface stimulation map of the forearm, determined from measurements in seven hemiplegic patients who had limited or absent voluntary movements of the fingers, thumb and wrist. The stimulation map for each patient was assessed with a conventional set of single pad Pals Platinum electrodes. Since the sites for the stimulation varied greatly between patients, the end result was a rather large multi-pad electrode. Modulating multi-pad electrode size, shape, position and individual pad stimulation parameters allows us to accommodate the diversity of the neural tissues in patients that need to be activated for functional grasp. This also allows asynchronous activation of different portions of the muscle and dynamic adaptation of the stimulation sites to appropriate underlying tissues during functional use. The validity of the determined stimulation map was tested in the same group of hemiplegic patients. The selected set of active pads resulted in fully functional and reproducible palmar and lateral grasps similar to healthy-like grasps.
AB - We designed a new surface multi-pad electrode for the electrical stimulation of the forearm that is effective in controlling functional grasp in hemiplegic patients. The electrode shape and size were designed on the basis of the surface stimulation map of the forearm, determined from measurements in seven hemiplegic patients who had limited or absent voluntary movements of the fingers, thumb and wrist. The stimulation map for each patient was assessed with a conventional set of single pad Pals Platinum electrodes. Since the sites for the stimulation varied greatly between patients, the end result was a rather large multi-pad electrode. Modulating multi-pad electrode size, shape, position and individual pad stimulation parameters allows us to accommodate the diversity of the neural tissues in patients that need to be activated for functional grasp. This also allows asynchronous activation of different portions of the muscle and dynamic adaptation of the stimulation sites to appropriate underlying tissues during functional use. The validity of the determined stimulation map was tested in the same group of hemiplegic patients. The selected set of active pads resulted in fully functional and reproducible palmar and lateral grasps similar to healthy-like grasps.
KW - Functional grasp
KW - multi-pad electrode
KW - stroke
UR - http://www.scopus.com/inward/record.url?scp=84880416919&partnerID=8YFLogxK
U2 - 10.1109/TNSRE.2013.2239662
DO - 10.1109/TNSRE.2013.2239662
M3 - Article
C2 - 23529101
AN - SCOPUS:84880416919
SN - 1534-4320
VL - 21
SP - 648
EP - 654
JO - IEEE Transactions on Neural Systems and Rehabilitation Engineering
JF - IEEE Transactions on Neural Systems and Rehabilitation Engineering
IS - 4
M1 - 6480884
ER -