TY - GEN
T1 - New multi-channel transcutaneous electrical stimulation technology for rehabilitation
AU - Keller, Thierry
AU - Lawrence, Marc
AU - Kuhn, Andreas
AU - Morari, Manfred
PY - 2006
Y1 - 2006
N2 - Transcutaneous (surface) electrical stimulation (TES) is a widely applied technique for muscle atrophy treatment, muscle force training, endurance training, pain treatment, functional movement therapy, and the restoration of motor functions. We present a new TES technology based on a multi-channel stimulation approach, which allows us to perform real-time spatial and temporal variations of the electrical current density on the skin surface and in deeper tissue layers. This new approach can generate a better muscle selectivity and improved muscle activation patterns compared to state of art TES systems, which operate with predetermined electrode positions. In simulations using a finite element model (FEM) of the distal arm we could show that the nerve activation in the muscle layer is not significantly influenced by the structure of the multi-channel electrode, if the gap between elements is less than 2 mm. Experiments in healthy volunteers allowed us to measure the selectivity of single finger activations. We could also show in stroke subjects that this novel multi-channel approach was able to generate selective finger and wrist extension movements that were strong enough to overcome flexion hyperactivity. For future applications in rehabilitation a full integration of the stimulation hardware into a garment sleeve would be helpful. Once fully integrated, this new technology has a high potential to increase the ease of use, stimulation and wear comfort. It is able to improve muscle selectivity compared to state of the art TES systems, and allows the implementation of a variety of new applications for the medical and consumer market.
AB - Transcutaneous (surface) electrical stimulation (TES) is a widely applied technique for muscle atrophy treatment, muscle force training, endurance training, pain treatment, functional movement therapy, and the restoration of motor functions. We present a new TES technology based on a multi-channel stimulation approach, which allows us to perform real-time spatial and temporal variations of the electrical current density on the skin surface and in deeper tissue layers. This new approach can generate a better muscle selectivity and improved muscle activation patterns compared to state of art TES systems, which operate with predetermined electrode positions. In simulations using a finite element model (FEM) of the distal arm we could show that the nerve activation in the muscle layer is not significantly influenced by the structure of the multi-channel electrode, if the gap between elements is less than 2 mm. Experiments in healthy volunteers allowed us to measure the selectivity of single finger activations. We could also show in stroke subjects that this novel multi-channel approach was able to generate selective finger and wrist extension movements that were strong enough to overcome flexion hyperactivity. For future applications in rehabilitation a full integration of the stimulation hardware into a garment sleeve would be helpful. Once fully integrated, this new technology has a high potential to increase the ease of use, stimulation and wear comfort. It is able to improve muscle selectivity compared to state of the art TES systems, and allows the implementation of a variety of new applications for the medical and consumer market.
UR - https://www.scopus.com/pages/publications/34047125443
U2 - 10.1109/IEMBS.2006.259399
DO - 10.1109/IEMBS.2006.259399
M3 - Conference contribution
C2 - 17946802
AN - SCOPUS:34047125443
SN - 1424400325
SN - 9781424400324
T3 - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
SP - 194
EP - 197
BT - 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
T2 - 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
Y2 - 30 August 2006 through 3 September 2006
ER -