Abstract
Hywind-Scotland is a wind farm in Scotland that for many reasons is at the leading edge of technology and is located at a paradigmatic study area for offshore wind energy assessment. The objective of this paper is to compute the Capacity Factor ( CF ) changes and instantaneous power generation changes due to seasonal and hourly fluctuations in air density. For that reason, the novel ERA5 reanalysis is used as a source of temperature, pressure, and wind speed data. Seasonal results for winter show that CF values increase by 3% due to low temperatures and denser air, with economical profit consequences of tens of thousands (US$). Hourly results show variations of 7% in air density and of 26% in power generation via FAST simulations, emphasizing the need to include air density in short-term wind energy studying.
Original language | English |
---|---|
Pages (from-to) | 2635 |
Number of pages | 1 |
Journal | Energies |
Volume | 12 |
Issue number | 13 |
DOIs | |
Publication status | Published - 2019 |
Keywords
- ERA5
- Air density
- Offshore wind energy
- FAST
- Scotland
Project and Funding Information
- Funding Info
- This work was financially supported by the Spanish Government through the MINECO project CGL2016-76561-R, (MINECO/ERDF, UE) and the University of the Basque Country (UPV/EHU, GIU 17/002). ERA5 hindcast data were downloaded at no cost from the Copernicus Climate Data Store. All the calculations and plots were made using R: https://www.r-project.org.