Towards a Functional Approach to the Assessment of Daily Life Physical Activity in Children: Are the PAQ-C and Fitbit Flex-2 Technically Adequate? Are the paq-c and fitbit flex-2 technically adequate?

Fotini Venetsanou, Kyriaki Emmanouilidou, Konstantinos Soutos, Sofoklis A. Sotiriou, Leire Bastida, Ana Moya, Antonis Kambas

Research output: Contribution to journalArticlepeer-review

15 Citations (Scopus)

Abstract

Considering the need for functional physical activity (PA) measures in PA settings, this study sought to determine the technical adequacy of the Physical Activity Questionnaire for Older Children (PAQ-C) and the Fitbit Flex-2, two instruments with promising features for wide use, using the Actigraph GT3X+ accelerometer as the criterion reference. A total of 218 Greek children (94 boys, 124 girls; mean age = 10.99 ± 1.52 years) volunteered to join in. Participants wore the PA trackers for seven days and completed the PAQ-C. Moreover, a sub-group (n = 60) recompleted the PAQ-C after a week. Results revealed acceptable internal consistency and excellent test–retest reliability for the PAQ-C. Regarding concurrent validity, weak to moderate correlations with PA parameters recorded by the GT3X+ were revealed for the total PAQ-C and were excellent for the Flex-2, while a Bland–Altman plot indicated good agreement. Finally, in alignment with relevant literature, significant gender, but no age, differences were found in participants’ PA records in all the tools applied. The above results support the use of the PAQ-C and the Fitbit Flex-2 in children. Considering that they shed light into different parameters of children’s habitual PA, their combined utilisation, providing comprehensive information, is strongly recommended.

Original languageEnglish
Article number8503
Pages (from-to)1-11
Number of pages11
JournalInternational Journal of Environmental Research and Public Health
Volume17
Issue number22
DOIs
Publication statusPublished - 17 Nov 2020

Keywords

  • Actigraph GT3X+
  • Reliability
  • Self-report
  • Validity

Project and Funding Information

  • Project ID
  • info:eu-repo/grantAgreement/EC/H2020/777082/EU/smart childhood Obesity CARing solution using IoT potential/Ocariot
  • Funding Info
  • This research was supported by the European Union’s HORIZON 2020 Programme (2014–2020) under ID n 777082, _x000D_ and by the Brazilian Ministry of Science, Technology and Innovation through Rede Nacional de Ensino e Pesquisa (RNP) under Ocariot.

Fingerprint

Dive into the research topics of 'Towards a Functional Approach to the Assessment of Daily Life Physical Activity in Children: Are the PAQ-C and Fitbit Flex-2 Technically Adequate? Are the paq-c and fitbit flex-2 technically adequate?'. Together they form a unique fingerprint.

Cite this