Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

An index combining respiratory rate and oxygenation to predict outcome of nasal high-flow therapy

  • Oriol Roca*
  • , Berta Caralt
  • , Jonathan Messika
  • , Manuel Samper
  • , Benjamin Sztrymf
  • , Gonzalo Hernández
  • , Marina García-De-Acilu
  • , Jean Pierre Frat
  • , Joan R. Masclans
  • , Jean Damien Ricard
  • *Autor correspondiente de este trabajo
  • Vall d'Hebron Research Institute
  • Hôpital Louis Mourier
  • Institut national de la santé et de la recherche médicale
  • UniversitéParis Diderot
  • Hôpital Antoine Béclère
  • Centre Chirurgical Marie Lannelongue
  • Hospital Virgen de la Salud
  • CHU de Poitiers
  • Université de Poitiers

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

591 Citas (Scopus)

Resumen

Rationale: One important concern during high-flow nasal cannula (HFNC) therapy in patients with acute hypoxemic respiratory failure is to not delay intubation. Objectives: To validate the diagnostic accuracy of an index (termed ROX and defined as the ratio of oxygen saturation as measured by pulse oximetry/FIO2 to respiratory rate) for determining HFNC outcome (need or not for intubation). Methods: This was a 2-year multicenter prospective observational cohort study including patients with pneumonia treated with HFNC. Identification was through Cox proportional hazards modeling of ROXassociation withHFNCoutcome. The most specific cutoff of the ROX index to predict HFNC failure and success was assessed. Measurements and Main Results: Among the 191 patients treated with HFNC in the validation cohort, 68 (35.6%) required intubation. The prediction accuracy of the ROX index increased over time (area under the receiver operating characteristic curve: 2 h, 0.679; 6 h, 0.703; 12 h, 0.759). ROX greater than or equal to 4.88 measured at 2 (hazard ratio, 0.434; 95% confidence interval, 0.264-0.715; P = 0.001), 6 (hazard ratio, 0.304; 95% confidence interval, 0.182-0.509; P,0.001), or 12 hours (hazard ratio, 0.291; 95% confidence interval, 0.161-0.524; P,0.001) after HFNC initiation was consistently associated with a lower risk for intubation. A ROX less than 2.85, less than 3.47, and less than 3.85 at 2, 6, and 12 hours of HFNC initiation, respectively, were predictors of HFNC failure. Patients who failed presented a lower increase in the values of the ROX index over the 12 hours. Among components of the index, oxygen saturation as measured by pulse oximetry/FIO2 had a greater weight than respiratory rate. Conclusions: In patients with pneumonia with acute respiratory failure treated with HFNC, ROX is an index that can help identify those patients with low and those with high risk for intubation.

Idioma originalInglés
Páginas (desde-hasta)1368-1376
Número de páginas9
PublicaciónAmerican Journal of Respiratory and Critical Care Medicine
Volumen199
N.º11
DOI
EstadoPublicada - 2019
Publicado de forma externa

ODS de las Naciones Unidas

Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

  1. ODS 3: Salud y bienestar
    ODS 3: Salud y bienestar

Huella

Profundice en los temas de investigación de 'An index combining respiratory rate and oxygenation to predict outcome of nasal high-flow therapy'. En conjunto forman una huella única.

Citar esto