Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Characterization of the NEURARM bio-inspired joint position and stiffness open loop controller

  • Nicola Vitiello*
  • , Tommaso Lenzi
  • , Joseph McIntyre
  • , Stefano Roccella
  • , Emanuele Cattin
  • , Fabrizio Vecchi
  • , Maria Chiara Carrozza
  • *Autor correspondiente de este trabajo
  • Sant'Anna School of Advanced Studies
  • Université Paris Cité

Producción científica: Capítulo del libro/informe/acta de congresoContribución a la conferenciarevisión exhaustiva

17 Citas (Scopus)

Resumen

This paper presents the characterization of the position and stiffness open loop controller for the NEURARM bio-inspired joint. A novel antagonistic non-linear actuation scheme is proposed for the NEURARM platform, a 2 DoF planar robotic arm that has been developed to imitate the principal functional features of the human arm for planar movements. The NEURARM joint has the actuation scheme based on a contractile element (a hydraulic piston) in series with a non-linear elastic element, able to mimic the force-elongation characteristic of the muscle-tendon complex. The non-linear spring is obtained by a linear tension spring rendered nonlinear by means of a specifically designed mechanism. Such actuation scheme allows the implementation of control strategies based on equilibrium point and impedance control hypotheses of human motor behavior. The preliminary results of the characterization of the open loop joint stiffness and position controller are presented.

Idioma originalInglés
Título de la publicación alojadaProceedings of the 2nd Biennial IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, BioRob 2008
Páginas138-143
Número de páginas6
DOI
EstadoPublicada - 2008
Publicado de forma externa
Evento2nd Biennial IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, BioRob 2008 - Scottsdale, AZ, Estados Unidos
Duración: 19 oct 200822 oct 2008

Serie de la publicación

NombreProceedings of the 2nd Biennial IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, BioRob 2008

Conferencia

Conferencia2nd Biennial IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, BioRob 2008
País/TerritorioEstados Unidos
CiudadScottsdale, AZ
Período19/10/0822/10/08

Huella

Profundice en los temas de investigación de 'Characterization of the NEURARM bio-inspired joint position and stiffness open loop controller'. En conjunto forman una huella única.

Citar esto