Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Compex motion - New portable transcutaneous stimulator for neuroprosthetic applications

  • M. R. Popovic
  • , T. Keller
  • , I. P.I. Pappas
  • , P. Y. Müller
  • Swiss Federal Institute of Technology Zurich
  • University of Toronto
  • Balgrist University Hospital
  • Compex SA

Producción científica: Capítulo del libro/informe/acta de congresoContribución a la conferenciarevisión exhaustiva

4 Citas (Scopus)

Resumen

A new portable and programmable transcutaneous electric stimulator Compex Motion that can be used for a wide range of Functional Electrical Stimulation (FES) applications is presented. The stimulator has four current regulated stimulation channels and has two input channels that can be configured as analog or digital input channels. The number of stimulation channels can be expanded in multiples of four (e.g. 8,12,16,...) by using 2,3,4, or more stimulators that are working in parallel. When the stimulators work in parallel their stimulation sequences and stimulation timings are fully synchronized. The Compex Motion stimulator can be programmed to generate arbitrary stimulation sequences. The programmed stimulation sequences are stored on readily exchangeable memory chip-cards. By replacing (exchanging) the chip-card the function of the stimulator is changed to provide another function or FES treatment. The stimulator can be controlled via any external sensor, sensory system or laboratory equipment with an output voltage in the range 0-5 V. The Compex Motion stimulator can be used to develop various custom-made neuroprostheses, neurological assessment devices, muscle exercise systems, and experimental set-ups for physiological studies. The Compex Motion stimulator is manufactured by the company Compex SA, located in Switzerland, and is currently undergoing clinical trials.

Idioma originalInglés
Título de la publicación alojada2001 European Control Conference, ECC 2001
EditorialInstitute of Electrical and Electronics Engineers Inc.
Páginas3945-3950
Número de páginas6
ISBN (versión digital)9783952417362
DOI
EstadoPublicada - 2001
Publicado de forma externa
Evento6th European Control Conference, ECC 2001 - Porto, Portugal
Duración: 4 sept 20017 sept 2001

Serie de la publicación

Nombre2001 European Control Conference, ECC 2001

Conferencia

Conferencia6th European Control Conference, ECC 2001
País/TerritorioPortugal
CiudadPorto
Período4/09/017/09/01

Huella

Profundice en los temas de investigación de 'Compex motion - New portable transcutaneous stimulator for neuroprosthetic applications'. En conjunto forman una huella única.

Citar esto