Demagnetization fault detection by means of hilbert huang transform of the stator current decomposition in PMSM

  • J. Rosero*
  • , L. Romeral
  • , J. A. Ortega
  • , J. C. Urresty
  • *Autor correspondiente de este trabajo
  • Polytechnic University of Catalonia

Producción científica: Capítulo del libro/informe/acta de congresoContribución a la conferenciarevisión exhaustiva

62 Citas (Scopus)

Resumen

This paper presents a study of the permanent magnet synchronous motor (PMSM) running under demagnetization. The simulation has been carried out by means of two dimensional (2-D) finite element analysis (FEA), and simulations results were compared with experimental results. The demagnetization fault is analyzed by means of decomposition of stator currents obtained at different speeds for torque change.

Idioma originalInglés
Título de la publicación alojada2008 IEEE International Symposium on Industrial Electronics, ISIE 2008
Páginas172-177
Número de páginas6
DOI
EstadoPublicada - 2008
Publicado de forma externa
Evento2008 IEEE International Symposium on Industrial Electronics, ISIE 2008 - Cambridge, Reino Unido
Duración: 30 jun 20082 jul 2008

Serie de la publicación

NombreIEEE International Symposium on Industrial Electronics

Conferencia

Conferencia2008 IEEE International Symposium on Industrial Electronics, ISIE 2008
País/TerritorioReino Unido
CiudadCambridge
Período30/06/082/07/08

ODS de las Naciones Unidas

Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

  1. ODS 7: Energía asequible y no contaminante
    ODS 7: Energía asequible y no contaminante

Huella

Profundice en los temas de investigación de 'Demagnetization fault detection by means of hilbert huang transform of the stator current decomposition in PMSM'. En conjunto forman una huella única.

Citar esto