Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

High-flow nasal cannula to prevent postextubation respiratory failure in high-risk non-hypercapnic patients: a randomized multicenter trial

  • Rafael Fernandez*
  • , Carles Subira
  • , Fernando Frutos-Vivar
  • , Gemma Rialp
  • , Cesar Laborda
  • , Joan Ramon Masclans
  • , Amanda Lesmes
  • , Luna Panadero
  • , Gonzalo Hernandez
  • *Autor correspondiente de este trabajo

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

65 Citas (Scopus)

Resumen

Background: Extubation failure is associated with increased morbidity and mortality, but cannot be safely predicted or avoided. High-flow nasal cannula (HFNC) prevents postextubation respiratory failure in low-risk patients. Objective: To demonstrate that HFNC reduces postextubation respiratory failure in high-risk non-hypercapnic patients compared with conventional oxygen. Methods: Randomized, controlled multicenter trial in patients who passed a spontaneous breathing trial. We enrolled patients meeting criteria for high-risk of failure to randomly receive HFNC or conventional oxygen for 24 h after extubation. Primary outcome was respiratory failure within 72-h postextubation. Secondary outcomes were reintubation, intensive care unit (ICU) and hospital lengths of stay, and mortality. Statistical analysis included multiple logistic regression models. Results: The study was stopped due to low recruitment after 155 patients were enrolled (78 received high-flow and 77 received conventional oxygen). Groups were similar at enrollment, and all patients tolerated 24-h HFNC. Postextubation respiratory failure developed in 16 (20%) HFNC patients and in 21 (27%) conventional patients [OR 0.69 (0.31–1.54), p = 0.2]. Reintubation was needed in 9 (11%) HFNC patients and in 12 (16%) conventional patients [OR 0.71 (0.25–1.95), p = 0.5]. No difference was found in ICU or hospital length of stay, or mortality. Logistic regression models suggested HFNC [OR 0.43 (0.18–0.99), p = 0.04] and cancer [OR 2.87 (1.04–7.91), p = 0.04] may be independently associated with postextubation respiratory failure. Conclusion: Our study is inconclusive as to a potential benefit of HFNC over conventional oxygen to prevent occurrence of respiratory failure in non-hypercapnic patients at high risk for extubation failure. Registered at Clinicaltrials.gov NCT01820507.

Idioma originalInglés
Número de artículo47
PublicaciónAnnals of Intensive Care
Volumen7
N.º1
DOI
EstadoPublicada - 1 dic 2017
Publicado de forma externa

ODS de las Naciones Unidas

Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

  1. ODS 3: Salud y bienestar
    ODS 3: Salud y bienestar

Huella

Profundice en los temas de investigación de 'High-flow nasal cannula to prevent postextubation respiratory failure in high-risk non-hypercapnic patients: a randomized multicenter trial'. En conjunto forman una huella única.

Citar esto