Resumen
In order to identify rigid body motions of floating offshore structures, output-only techniques are very useful for developing low-cost intermediate-scale experimental activities directly into the sea, instead of wave tanks. A crucial parameter, however, is the length of the response records used as input for the identification process, since short records may result in significant loss of accuracy, while long ones may be incompatible with the assumption of stationarity of the sea state. This work presents a sensitivity study conducted on a numerical model of a spar structure, identified by means of Enhanced Frequency Domain Decomposition method. An overview on the efficiency of the method is given for various lengths of response record, along with practical indications on the minimum values acceptable.
| Idioma original | Inglés |
|---|---|
| Páginas (desde-hasta) | 930-935 |
| Número de páginas | 6 |
| Publicación | Procedia Engineering |
| Volumen | 199 |
| DOI | |
| Estado | Publicada - 2017 |
| Evento | 10th International Conference on Structural Dynamics, EURODYN 2017 - Rome, Italia Duración: 10 sept 2017 → 13 sept 2017 |
Palabras clave
- Operational Modal Analysis
- Output-only dynamic identification
- Enhanced Frequency Domain Decomposition method
- Floating spar structures
Huella
Profundice en los temas de investigación de 'Output-only identification of rigid body motions of floating structures: a case study: A case study'. En conjunto forman una huella única.Citar esto