Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Portable microfluidic impedance biosensor for SARS-CoV-2 detection

  • Soroush Laleh
  • , Bergoi Ibarlucea*
  • , Marlena Stadtmüller
  • , Gianaurelio Cuniberti
  • , Mariana Medina-Sánchez*
  • *Autor correspondiente de este trabajo
  • Leibniz Institute for Solid State and Materials Research Dresden
  • Technische Universität Dresden

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

25 Citas (Scopus)

Resumen

Pandemics as the one we are currently facing, where fast-spreading viruses present a threat to humanity, call for simple and reliable methods to perform early diagnosis, enabling detection of very low pathogen loads even before symptoms start showing in the host. So far, standard polymerase chain reaction (PCR) is the most reliable method for doing so, but it is rather slow and needs specialized reagents and trained personnel to operate it. Additionally, it is expensive and not easily accessible. Therefore, developing miniaturized and portable sensors which perform early detection of pathogens with high reliability is necessary to not only prevent the spreading of the disease but also to monitor the effectiveness of the developed vaccines and the appearance of new pathogenic variants. Thus, in this work we develop a sensitive microfluidic impedance biosensor for the direct detection of SARS-CoV-2, towards a mobile point-of-care (POC) platform. The operational parameters are optimized with the aid of design-of-experiment (DoE), for an accurate detection of the viral antigens using electrochemical impedance spectroscopy (EIS). We perform the biodetection of buffer samples spiked with fM concentration levels and validate the biosensor in a clinical context of relevance by analyzing 15 real patient samples up to a Ct value (cycle threshold) of 27. Finally, we demonstrate the versatility of the developed platform using different settings, including a small portable potentiostat, using multiple channels for self-validation, as well as with single biosensors for a smartphone-based readout. This work contributes to the rapid and reliable diagnostics of COVID-19 and can be extended to other infectious diseases, allowing the monitoring of viral load in vaccinated and unvaccinated people to anticipate a potential relapse of the disease.

Idioma originalInglés
Número de artículo115362
PublicaciónBiosensors and Bioelectronics
Volumen236
DOI
EstadoPublicada - 15 sept 2023
Publicado de forma externa

ODS de las Naciones Unidas

Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

  1. ODS 3: Salud y bienestar
    ODS 3: Salud y bienestar

Huella

Profundice en los temas de investigación de 'Portable microfluidic impedance biosensor for SARS-CoV-2 detection'. En conjunto forman una huella única.

Citar esto