Treating drop-foot in hemiplegics: The role of matrix electrode

  • Christine Azevedo-Coste*
  • , G. Bijelic
  • , L. Schwirtlich
  • , D. B. Popovic
  • *Autor correspondiente de este trabajo
  • Université de Montpellier II
  • University of Belgrade
  • Institute for Rehabilitation ‘Dr Miroslav Zotovic’
  • Aalborg University

Producción científica: Capítulo del libro/informe/acta de congresoContribución a la conferenciarevisión exhaustiva

9 Citas (Scopus)

Resumen

We present advantages of the “intelligent matrix electrode” for providing selective correction of drop-foot in hemiplegic individuals. The matrix electrode which integrates stimulating and sensing parts could allow the emulation of the appropriate electrode shape and size; thereby, provision of selective stimulation that leads to functional movement and online adaptation of the electrode during the application. The need for selective stimulation follows recent findings about therapeutic effects of electrical stimulation in neurorehabilitation. The matrix electrode comprises small fields that can be made conductive and a controller that allows computerized selection of the fields being conductive. Here we present results from a study in nine hemiplegics. The matrix electrode was positioned over the peroneal nerve and primary dorsiflexor muscles and we estimated the movement of the foot by measuring the ankle joint angle. We found that the branched tree type shape and size of the electrode vary substantially when stimulating over the dorsiflexor muscles individuals in the study. We confirmed very high sensitivity to the position of small electrode when stimulating over the nerve. This indicates that the use of “intelligent matrix electrode” is favorable compared with conventional electrodes since it can adapt to individual and secure selective stimulation.

Idioma originalInglés
Título de la publicación alojadaIFMBE Proceedings
EditoresTomaz Jarm, Peter Kramar, Anze zupanic
EditorialSpringer Verlag
Páginas654-657
Número de páginas4
Edición1
ISBN (versión impresa)9783540730439
DOI
EstadoPublicada - 2007
Publicado de forma externa
Evento11th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2007 - Ljubljana, Eslovenia
Duración: 26 jun 200730 jun 2007

Serie de la publicación

NombreIFMBE Proceedings
Número1
Volumen16
ISSN (versión impresa)1680-0737
ISSN (versión digital)1433-9277

Conferencia

Conferencia11th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2007
País/TerritorioEslovenia
CiudadLjubljana
Período26/06/0730/06/07

Huella

Profundice en los temas de investigación de 'Treating drop-foot in hemiplegics: The role of matrix electrode'. En conjunto forman una huella única.

Citar esto