Skip to search boxSkip to navigationSkip to main content

The effects of increasing effective airway diameter on weaning from mechanical ventilation in tracheostomized patients: A randomized controlled trial

  • Gonzalo Hernandez(corresponding author)
    ,
  • Ana Pedrosa
    ,
  • Ramon Ortiz
    ,
  • Maria Del Mar Cruz Accuaroni
    ,
  • Rafael Cuena
    ,
  • Concepción Vaquero Collado
*Corresponding author for this work
  • Hospital Infanta Sofía
    ,
  • Hospital Virgen de la Salud
    ,
  • Hospital General Universitario de Ciudad Real
    ,
  • Medical Council
Research Output:
Contribution to journal
Article
Research
Peer-review

Abstract

Purpose: To determine the effects of deflating the tracheal cuff during disconnections from mechanical ventilation (MV) in tracheostomized patients. Methods: This was a single-center, randomized trial conducted in a general ICU of a tertiary hospital with regional referral for trauma patients. Patients at high risk of aspiration based on the drink test were excluded. Critically ill tracheostomized patients were randomized to have the tracheal cuff deflated or not during spontaneous breathing trials. Weaning was protocolized on progressive T-tube trials, and patients were considered weaned after 24 consecutive hours disconnected from MV. The primary end point was time to definitive withdrawal of MV; secondary end points were ventilator-associated respiratory infection (pneumonia and/or tracheobronchitis) and swallowing function. Statistical analyses included Cox proportional risk models. Results: We randomized 195 patients and 181 patients completed the study (94 patients with deflated cuff and 87 with inflated cuff). Variables independently related to weaning time in the multivariate analysis were tracheostomy-to-first MV disconnection time (HR 0.5, 95 % CI 0.3-0.8; p < 0.01) and cuff deflation (HR 2.2, 95 % CI 1.5-3; p < 0.01). Respiratory infection was lower in the deflated group (20 vs. 36 %; p = 0.02). Swallowing function improved more in the deflated group (31 vs. 22 %; p = 0.02). Conclusion: Under the conditions of our protocol, deflating the tracheal cuff in tracheostomized patients shortens weaning, reduces respiratory infections, and probably improves swallowing.

Research Output Information

Output type

Research Output:
Contribution to journal
Article
Research
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 1063-1070 (8 pages)

Journal (Volume, Issue Number)

Intensive Care Medicine (Volume 39, Issue 6)

Publication milestones

  • Published - 06/2013

Publication status

Published - 06/2013

ISSN

0342-4642

Publication IDs

  • Scopus: 84878016363
  • PubMed: 23471512

Funding Details

Acknowledgments We thank all the patients and medical and nursing staff for their cooperation. This study was supported in part by Fundación para la Investigación de Castilla-La Mancha (FI-SCAM) (grant PI-2009/71). The study protocol was approved by the Healthcare Service of Castilla-La Mancha (SESCAM) to which the tertiary hospital Virgen de la Salud is affiliated.
FunderFunding number
Fundación para la Investigación de Castilla-La Mancha
PI-2009/71

Sustainable Development Goals

  • SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well

Publication metrics

Metrics

SciVal
citations
43
Scopus
citations
SciVal
FWCI
0.77
SciVal
Author count
9
SciVal
Paper percentile
66

PlumX, opens in new tab

Citation count
46
Captures
171
Social media
130