<p>Reinforced concrete structures came to Spain in the late-19th century, somewhat after the development of this new construction material elsewhere in Europe. Their introduction was pioneered in industrialized areas, especially Northern Spain, under systems first patented in other European countries. Local constructors built structures under patents with little or no explanations to account for calculation, design, and construction technique. Some of these buildings from the recent past are now listed buildings. This study centres on three construction projects under patented systems: Our Lady of “La Antigua”, Orduña (Monier system), “La Ceres” flour mill, Bilbao (Hennebique system), and Alhóndiga, Bilbao (Blanc system). Preliminary structural studies analyzed morphology, reinforcements, concrete strength and pathological processes in each structure. Their results are compared with information taken from the patent systems in use at the time. This useful information on the structures, which may be expanded in future research, clearly describes the relationship between patent specifications and reality.</p>
Research Output Information
Tipo de resultado
Publicación:
Contribución a una revista
Artículo
Investigación
Revisión por expertosIdioma original
InglésPáginas desde-hasta (Número de páginas)
Páginas 310-319 (10 páginas)Revista (Volumen, Número de Edición)
International Journal of Architectural Heritage (Volumen 12, Número 3)Hitos de publicación
- Publicada - 03/04/2018
Estado de publicación
Publicada - 03/04/2018
ISSN
1558-3058ID de publicación
- Scopus: 85023201320
Funding Details
We express our gratitude to the Basque Regional Government (IT781-13 Research Group) and to the Vice-Rectorate of Investigation of the University of the Basque Country (UPV/EHU) for grant PIF 2013. Furthermore, the researchers would like to thank the authors (engineers, architects, municipal councils and owners of the buildings) of the pathological studies for their contribution to this study. We express our gratitude to the Basque Regional Government (IT781-13 Research Group) and to the Vice-Rectorate of Investigation of the University of the Basque Country (UPV/EHU) for grant PIF 2013.
FundersFunding numbers
Basque Regional Government
IT781-13
EHU
PIF 2013
UPV
-Publication metrics
Métricas
SciVal
FWCI
1.68
SciVal
Número de autores
4
SciVal
Percentil de artículo
84
SciVal
citaciones
8
PlumX, se abre en una pestaña nueva
Número de citas
8
Capturas
26