Effect of Zero-Sequence Voltage on the Maximum Average Neutral-Point Current Limit of Neutral-Point-Clamped Converters
- Neha Beniwal,
- Glen G. Farivar,
- ,
- Naga Brahmendra Yadav Gorla,
- Josep Pou
- Nanyang Technological University,
Abstract
In this paper, the effect of min-max zero-sequence voltage (ZSV) injection on the maximum average neutral-point (NP) current control limits of a neutral-point-clamped (NPC) converter is analyzed. These current limits determine the stable operating range of the NPC converter in applications that impose a nonzero average NP current, like-NPC converters feeding multiterminal dc loads, back-to-back-connected NPC converter-based wind and high voltage dc transmission systems, etc. Previously, a dual-mode modulation technique was implemented in the literature which provided the maximum average NP current limits without considering the ZSV effect. As the ZSV injection affects the NP duty cycles, and in turn the NP current, it is necessary to analyze and quantify its effect. In this paper, the effect of ZSV on the current limits is analytically calculated. Simulation results are obtained in MATLAB/Simulink environment to validate the derived analytical equations.
Research Output Information
Tipo de resultado
Idioma original
InglésHitos de publicación
- Publicada - 13/10/2021
Estado de publicación
Editorial
IEEE Computer Society, Estados UnidosSerie de publicación
- Nombre de serie de publicación: IECON Proceedings (Industrial Electronics Conference)
Volumen: 2021-October
ISBN (electrónico)
9781665435543ID de publicación
- Scopus: 85119470918
Título de publicación principal
IECON 2021 - 47th Annual Conference of the IEEE Industrial Electronics SocietyFunding Details
Sustainable Development Goals
- ODS 7: Energía asequible y no contaminante