Saltar a casilla de búsquedaSaltar a navegaciónIr directamente al contenido principal

Fixating the pelvis in the horizontal plane affects gait characteristics

  • Jan F. Veneman(autor correspondiente)
    ,
  • Jasper Menger
    ,
  • Edwin H.F. van Asseldonk
    ,
  • Frans C.T. van der Helm
    ,
  • Herman van der Kooij
*Autor correspondiente de este trabajo
  • University of Twente
    ,
  • Delft University of Technology
Publicación:
Contribución a una revista
Artículo
Investigación
Revisión por expertos

Abstract

In assistive devices for neuro-rehabilitation, natural human motions are partly restricted by the device. This may affect the normality of walking during training. This research determines effects on gait of fixating the pelvis translations in the horizontal plane during treadmill walking. Direct effects on the motion of the pelvis and external forces acting on the pelvis were measured. Several gait descriptors (step parameters, trunk angles and a ground reaction force parameter) were defined and measured to indicate changes. We observed the effect of the pelvis fixation on these parameters while varying gait velocity (0.35, 0.60 and 0.90 m/s). It was shown that the fixation caused a reduction of step width by 33%, and an increase of step length of 19%. Sagittal and coronal trunk rotations changed with +68% and -54% respectively. The fixation also significantly changed the effect of speed on most descriptors. It can therefore be concluded that a fixation of the pelvis severely affects gait dynamics and that it should be avoided if natural walking should be possible during training.

Research Output Information

Tipo de resultado

Publicación:
Contribución a una revista
Artículo
Investigación
Revisión por expertos

Idioma original

Inglés

Páginas desde-hasta (Número de páginas)

Páginas 157-163 (7 páginas)

Revista (Volumen, Número de Edición)

Gait and Posture (Volumen 28, Número 1)

Hitos de publicación

  • Publicada - 07/2008

Estado de publicación

Publicada - 07/2008

ISSN

0966-6362

ID de publicación

  • Scopus: 44149087106
  • PubMed: 18207406

Funding Details

This research is supported by the NWO (vernieuwings-impuls 2001, granted to Dr. H. van der Kooij) and by the Institute for Biomedical Technology, Enschede.
FundersFunding numbers
Institute for Biomedical Technology (BMTI)
-
NWO
-

Publication metrics

Métricas

SciVal
FWCI
1.22
SciVal
Número de autores
5
SciVal
Percentil de artículo
76
SciVal
citaciones
62

PlumX, se abre en una pestaña nueva

Capturas
104
Número de citas
62