Saltar a casilla de búsquedaSaltar a navegaciónIr directamente al contenido principal

H-Man: A planar, H-shape cabled differential robotic manipulandum for experiments on human motor control

  • Domenico Campolo(autor correspondiente)
    ,
  • Paolo Tommasino
    ,
  • Kumudu Gamage
    ,
  • Julius Klein
    ,
  • Charmayne M.L. Hughes
    ,
  • Lorenzo Masia
*Autor correspondiente de este trabajo
  • Nanyang Technological University
Publicación:
Contribución a una revista
Artículo
Investigación
Revisión por expertos

Abstract

In the last decades more robotic manipulanda have been employed to investigate the effect of haptic environments on motor learning and rehabilitation. However, implementing complex haptic renderings can be challenging from technological and control perspectives. We propose a novel robot (H-Man) characterized by a mechanical design based on cabled differential transmission providing advantages over current robotic technology. The H-Man transmission translates to extremely simplified kinematics and homogenous dynamic properties, offering the possibility to generate haptic channels by passively blocking the mechanics, and eliminating stability concerns. We report results of experiments characterizing the performance of the device (haptic bandwidth, Z-width, and perceived impedance). We also present the results of a study investigating the influence of haptic channel compliance on motor learning in healthy individuals, which highlights the effects of channel compliance in enhancing proprioceptive information. The generation of haptic channels to study motor redundancy is not easy for actual robots because of the needs of powerful actuation and complex real-time control implementation. The mechanical design of H-Man affords the possibility to promptly create haptic channels by mechanical stoppers (on one of the motors) without compromising the superior backdriveability and high isotropic manipulability. This paper presents a novel robotic device for motor control studies and robotic rehabilitation. The hardware was designed with specific emphasis on the mechanics that result in a system that is easy to control, homogeneous, and is intrinsically safe for use.

Research Output Information

Tipo de resultado

Publicación:
Contribución a una revista
Artículo
Investigación
Revisión por expertos

Idioma original

Inglés

Páginas desde-hasta (Número de páginas)

Páginas 285-297 (13 páginas)

Revista (Volumen, Número de Edición)

Journal of Neuroscience Methods (Volumen 235)

Hitos de publicación

  • Publicada - 30/09/2014

Estado de publicación

Publicada - 30/09/2014

ISSN

0165-0270

ID de publicación

  • Scopus: 84907354319
  • PubMed: 25058923

Funding Details

This work was partly supported by the ‘H-Man’ project (NMRC/BnB/0006b/2013), Ministry of Health, Singapore.
FunderFunding numbers
Ministry of Health, Government of Singapore
-

Publication metrics

Métricas

SciVal
FWCI
0.85
SciVal
Número de autores
6
SciVal
Percentil de artículo
67
SciVal
citaciones
59

PlumX, se abre en una pestaña nueva

Número de citas
59
Capturas
88