Abstract

The cooperation of Dispersed Generation (DG) units with storage devices to meet controllable loads constitutes a Microgrid. Microgrids are Low Voltages (LV) or in some cases Medium Voltages (MV) networks. The unique feature of Microgrids is that although they operate mostly interconnected to the upper level voltage distribution network, they can be automatically transferred to islanded mode, in case of faults in the upstream network. Microgrid structure is able to unlock the full potential of Distributed Energy Resources (DER) and allows the full exploitation of their advantages. The purpose of this paper is to study the power quality of the Combined Heat and Power (CHP) system installed in the frame of EU-DEEP project inside the premises of the National Technical University of Athens (NTUA). The Microgrid system also contains batteries with inverters and critical loads. The power quality is studied by taking into consideration voltage magnitude variations, frequency variations, voltage unbalance, voltage fluctuations, as well as light flicker and harmonic distortion. Furthermore, the transitions between the islanded operation mode and the connected one are studied. The measurements are compared with the limits given by power quality Standards, especially ΕΝ 50160. The power quality analysis came to the conclusion that the current harmonic distortion is the main disturbance, because a high current Total Harmonic Distortion (THD) factor was observed. In addition, it was observed that the flicker exceeds the Standards' limits in the islanded mode. At last, it should be noted that distributed power units like the one examined can improve continuity and support the main power supply in the event of a supply outage.

Research Output Information

Tipo de resultado

Publicación:
Capítulo del libro/informe/acta de congreso
Contribución a la conferencia
Investigación
Revisión por expertos

Subtítulo de publicación principal

Integrating Supergrids and Microgrids

Idioma original

Inglés

Hitos de publicación

  • Publicada - 2011

Estado de publicación

Publicada - 2011

Serie de publicación

  • Nombre de serie de publicación: CIGRE 2011 Bologna Symposium - The Electric Power System of the Future: Integrating Supergrids and Microgrids
9782858731657

ID de publicación

  • Scopus: 84877285727

Título de publicación principal

CIGRE 2011 Bologna Symposium - The Electric Power System of the Future

Publication metrics

Métricas

SciVal
citaciones
1
SciVal
FWCI
0.40
SciVal
Número de autores
8
SciVal
Percentil de artículo
52

PlumX

Número de citas
1
Capturas
8