Saltar a casilla de búsquedaSaltar a navegaciónIr directamente al contenido principal

Sizing limitations of ultrasonic array images for non-sharp defects and their impact on structural integrity assessments

  • Shivaprasad Shridhara Bhat(autor correspondiente)
    ,
  • Jie Zhang
    ,
*Autor correspondiente de este trabajo
  • University of Bristol
    ,
  • Department of Mechanical Engineering
Publicación:
Contribución a una revista
Artículo
Investigación
Revisión por expertos

Acceso abierto

Abstract

Existing structural integrity assessment procedures typically assume flaws to be infinitely sharp when they cannot be considered as local thinned areas. This assumption is often over-conservative, resulting in a pessimistic assessment of structural components and a significant underestimation of their margins of safety against fracture. One of the main challenges while adopting non-destructive evaluation techniques is distinguishing between sharp cracks (e.g., fatigue) and non-sharp defects and identifying the more severe ones. Towards this broader challenge, the present work aims to examine the sizing limitation and accuracy of ultrasonic array image-based techniques for non-sharp defects (surface breaking u-notches) and investigate how these measurements would affect the structural integrity assessment of components. Parametric numerical simulations and experimental measurements are performed to generate full-matrix capture datasets, which are then processed using the total focusing method to form an image. The image-based sizing approach is shown to perform efficiently for notch depths higher than the inspection wavelength (λL), i.e. as small as 0.2 mm, and semi-notch widths as small as 0.1 mm. The influence of ultrasonic measurements on structural integrity assessments is highlighted using different case studies in the context of non-sharp defects of fatigue and fracture strength estimates. For the cases under analysis, resolving non-sharp defects led up to 5× and 3× values of effective fracture toughness and fatigue strength, respectively. We have also seen that a 30 % uncertainty in semi-notch width sizing would result in a 30 % and 20 % error in fatigue strength and fracture toughness estimations, respectively.

Research Output Information

Tipo de resultado

Publicación:
Contribución a una revista
Artículo
Investigación
Revisión por expertos

Idioma original

Inglés

Número de artículo

103625

Revista (Volumen, Número de Edición)

Theoretical and Applied Fracture Mechanics (Volumen 122)

Hitos de publicación

  • Publicada - 12/2022

Estado de publicación

Publicada - 12/2022

ISSN

0167-8442

ID de publicación

  • Scopus: 85140069635

Funding Details

The authors would also like to thank the UK Engineering and Physical Sciences Research Council (EPSRC) for its financial support through grant number EP/S012362/1. The lead author would like to thank the Advanced Computing Research Centre (ACRC) at the University of Bristol ( www.bristol.ac.uk/acrc ) for providing access to the Blue Crystal 4 & Blue Pebble GPU clusters for performing numerical simulations. The authors would also like to thank Jose Antonio Balbin (University of Sevila, Spain) & Greg Thorwald (Quest Integrity USA LLC) for sharing the raw data presented as part of the case studies in Section 5 . The authors would also like to thank the UK Engineering and Physical Sciences Research Council (EPSRC) for its financial support through grant number EP/S012362/1. The lead author would like to thank the Advanced Computing Research Centre (ACRC) at the University of Bristol (www.bristol.ac.uk/acrc) for providing access to the Blue Crystal 4 & Blue Pebble GPU clusters for performing numerical simulations. The authors would also like to thank Jose Antonio Balbin (University of Sevila, Spain) & Greg Thorwald (Quest Integrity USA LLC) for sharing the raw data presented as part of the case studies in Section 5.
FundersFunding number
Advanced Computing Research Centre
-
EPSRC
EP/S012362/1
University of Bristol
-

Publication metrics

Métricas

Descargar estadísticas
Número de descargas
8
SciVal
FWCI
0.34
SciVal
Número de autores
3
SciVal
Percentil de artículo
42
SciVal
citaciones
5

PlumX, se abre en una pestaña nueva

Número de citas
5
Capturas
12